Pipe sizing and friction loss calculators
Irrigation pipe sizing and friction loss
Compare true internal bores, calculate velocity and account for both pipe and fitting losses.
Read the worked exampleCalculate pipe flow, velocity and friction loss, then check the pressure available to the system. Explore pipe hydraulics tools for irrigation designers, pump retailers and engineers.
Read a public example, check the required inputs, or explore a calculator. New accounts require approval; start a 14-day free trial.
Guides & worked examples
Follow the inputs, equations and assumptions before working on a project design.
Pipe sizing and friction loss calculators
Compare true internal bores, calculate velocity and account for both pipe and fitting losses.
Read the worked exampleA short introduction to what Tenselo covers in this category.
Video summary: Flow, velocity, pipe volume, Darcy-Weisbach and Hazen-Williams friction loss, fittings, elevation and preliminary pipe selection.
Hazen-Williams · PE/PVC/steel
This abbreviated result preview omits some design inputs. Use the linked worked examples for reproducible arithmetic; review the complete inputs, product data and warnings for a project design.
Keeps flow fast enough to self-clean, slow enough to dodge erosion and surge.
Hazen-Williams loss in m, kPa and bar — so pump head and class selection are defensible.
Surge and column-separation tools flag the risk before it cracks a main.
Pipe hydraulics describes how flow, velocity, pressure and elevation interact in a pipe system. Start with the operating flow and the actual internal diameter, calculate losses along the route, and check the pressure available at the critical outlet.
Pressure head is p/(ρg): pressure p divided by fluid density ρ and gravitational acceleration g. For water at an assumed density of 1,000 kg/m³ with g = 9.81 m/s², one metre of pressure head is 9.81 kPa. Elevation head also belongs in the energy balance; an uphill route requires more supply head than the same route on level ground.
Nominal size is a product designation; it may differ from the internal bore used in a calculation. The worked pipe-sizing example compares 100 mm and 125 mm internal bores at 10 L/s, showing velocity, Darcy–Weisbach loss and fitting loss separately. Its assumed friction factor is for arithmetic comparison, not a product selection.
A constant-flow mainline carries the full design flow throughout. Flow falls after each emitter along a drip lateral, so losses need to reflect each segment's flow. See the segmented drip-lateral example before applying a full-flow mainline result to emitting pipework.
Combine pipe, fitting and equipment losses with elevation and the required outlet pressure. Review operating cases, maximum pressure and transients separately. Low steady-state loss does not establish protection against water hammer. Carry the assessed flow and head into pump sizing.
Use this pipe volume calculator example to find stored water and ideal fill time, then relate the same 100 mm actual internal bore and 10 L/s duty to flow rate and pipe velocity.
Design questionWhat happens inside a 500 m main at 10 L/s?
Calculated result. At 10 L/s, water travels through the 100 mm bore at 1.273 m/s. The pipe stores 7.85 L/m, or about 3,927 L over 500 m, with an ideal volume-divided-by-flow fill time of 6.5 minutes.
This static, hypothetical example was run in Tenselo HYD-009 and HYD-012 on 15 September 2026. Live project calculations and PDF reports require authorised application access.
Tenselo includes pipe volume and fill-time, flow and velocity, Darcy-Weisbach and Hazen-Williams friction-loss, fitting-loss, elevation, surge, air-valve, preliminary pipe-selection and water-meter sizing calculations.
It uses the actual internal diameter and pipe length to calculate cross-sectional area and stored volume. Dividing stored volume by steady flow gives an ideal fill-time check; real filling also depends on air release, pump duty, friction and pressure.
Flow rate is the volume moving per unit time, while velocity is the water speed inside the pipe. They are connected by Q = A x v, so the actual internal diameter is required when converting between them.
It needs the flow, actual internal diameter, pipe length and the selected loss method. Material roughness or Hazen-Williams C value, water properties, fittings, elevation and equipment losses may also be required for the complete system check.
The website provides public guides and static worked examples. Apply for an account to run project calculations; new applications require approval.
Confirm the friction method, diameter convention, operating cases and required outputs. The software selection guide explains how to evaluate metric calculations and reports alongside any CAD or network modelling requirements.
View the worked sample and downloadable PDF for the inputs, calculation result, manufacturer references and limitations.
HYD-029, Water Meter Sizing, supports water-system designers assessing meter size, flow range and installation straight lengths from the operating flow, pipe size and selected technology. It also provides indicative brand and output options for review.
Record the normal operating flow and check the expected low and peak flows. The pipe's nominal diameter alone is not a meter selection. Review the candidate meter's rated flow range, pressure loss, water conditions and installation requirements against the current manufacturer data.
The calculator includes mechanical and static-meter options. Its size and straight-length guidance supports preliminary selection; confirm the exact model, orientation, upstream fittings, available straight pipe and any required pattern approval with the supplier. Different instruments can have different installation requirements even when their nominal size matches.
Establish whether the project needs a local register, pulse output or communications. For a pulse-output meter, use the flowmeter K-factor and pulse-scaling calculator to convert frequency to flow or a pulse count to volume. Match the K-factor units to the meter configuration and the receiving counter.
The flowmeter straight-length check considers the meter type and upstream disturbance. Use these calculations with the supplier's model-specific instructions. New accounts require approval; running project calculations requires authorised application access. See availability and registration.
Every calculator in this category, by its reference code. Running them requires an approved Tenselo account with access to the relevant calculators.
Heat loss & surface temperature of an insulated (and bare) horizontal pipe
Crown vacuum, cavitation/air-break check and priming volume for a siphon pipeline
AS 4087 / AS 2129 / ANSI / ISO drilling: OD, PCD, bolts, holes
Fusion pressures + times and a joint-count / crew / days estimate
Smallest DN whose total HW loss <= your budget
Smallest pressure class covering operating + surge
Fluid + flow + velocity -> recommended pipe (viscosity-aware Darcy-Weisbach)
Smallest standard DN that meets your target velocity
Water held in a pipe run and the time to fill or drain it at a flow
Dig, bedding and spoil volumes for a pipe trench (with batter)
Pipe area, velocity, flow conversions
Alternative to Hazen-Williams for non-water or high-precision
Pipe head loss + fittings allowance
Gravity flow for an AU pipe (check OR size for a flow) + vacuum-collapse + air valves
Even-spaced outlets along a header
Fitting head loss h_L = K * v^2 / 2g
Laminar vs turbulent
H_v = v^2 / 2g
Flow in an open channel
Flow through a sharp-edged orifice from its diameter + head
Flow under a sluice / slide gate lifted off the bottom (L/s + ML/day)
Time to gravity-drain a tank through an outlet orifice
Channel / spillway flow over a rectangular weir (L/s + ML/day)
Max support spacing AND the load each support carries, for an above-ground pipe full of water
Pipe growth/shrink, expansion-loop leg and anchor force vs temperature
Bend/tee/cap thrust -> bearing area, block size & concrete volume
Surge on valve closure + static head -> total at the valve
Size the meter + straight pipe lengths by flow & pipe size; pick a brand/output
Peak day/hour demand + fire flow & storage, governing main size (WSA 03 / AS 2419.1)
Flow through intake & process screens: open area, screen area, velocity checks and head loss for wedge-wire, sidehill, suction, drum and well screens
Size an anti-vortex plate for a foot valve / pump in shallow water, or a tank outlet to recover dead storage
Tell us about yourself and the work you do. We review each application before granting access. The 14-day trial requires no payment card.
After approval, verify your email and set your password. Your account shows the time left in your trial. When it ends, choose a paid plan and review the price in Stripe before subscribing.
Start 14-day free trialAlready approved? Sign in. For company licences, email sales@tenselo.com.au.