Cable sized to the standard — every time.
Cable sizing to AS/NZS 3008, voltage drop, protection and arc-flash safety — for the electricians who wire pump stations, bores and treatment plants.
Electrical & solar in Tenselo
A short introduction to what Tenselo covers in this category.
10 mm² Cu cable
AS/NZS 3008 · 40 A Type C MCB · 415 V 3-phase
These figures come from the Tenselo engine. Every result Tenselo produces shows the inputs it used and the method behind it, so the work can be checked rather than taken on trust.
Why it matters on the job
AS/NZS 3008 compliant
Current-carrying capacity and volt-drop worked to the standard, with the earth from Table 5.1.
Protection that coordinates
MCB / fuse rating sized to the load and the cable, not picked by feel.
Arc-flash & fault aware
Fault-loop impedance and arc-flash tools keep the install safe and certifiable.
23 Electrical Power & Cable calculators
Every calculator in this category, by its reference code. Running them needs a Tenselo subscription — subscriptions open soon.
-
ELE-001 Arc Flash (IEEE 1584-2018)
Incident energy, arcing current & arc-flash boundary - IEEE 1584-2018 empirical model
-
ELE-002 Arc Flash Incident Energy (Ralph Lee)
Incident energy & arc-flash boundary by the IEEE 1584 Lee method (conservative screening)
-
ELE-003 Generator Fault Current
Sub-transient / transient short-circuit current from Xd'' and Xd'
-
ELE-004 Transformer Calculator
kVA, full-load current (primary & secondary), kW and turns ratio
-
ELE-005 Transformer Fault Current
Symmetrical 3-phase fault at the LV terminals from kVA and %Z (infinite or finite source)
-
ELE-006 Voltage Rise (inverter export, AS/NZS 3008/4777)
Inverter export voltage rise 1ph/3ph, % of nominal, and the smallest cable for the limit
-
ELE-007 Cable Sizing (AS/NZS 3008)
Current rating, voltage drop, earth-fault loop, short-circuit + step-by-step calculations, to AS/NZS 3008.1.1 + 3000
-
ELE-008 Cable Sizing (quick)
Motor FLA + voltage drop (AS/NZS 3008 mV/A.m method)
-
ELE-009 Cable Tray Sizing & Selection
Size or check a cable tray from the cable runs - width, depth, support span, load, material for the environment and fasteners (AS/NZS 61537 / 3000 / 1170)
-
ELE-010 Conduit Fill
Minimum conduit for any AU cable - single-core (Cu/Al, PVC/XLPE) or multicore circular (orange PVC, XLPE) - real ODs, AS/NZS 3000 space factors
-
ELE-011 Solenoid Cable
Size the field cable, or check a size -- voltage at coil
-
ELE-012 Voltage Drop (AS/NZS 3008)
Cable volt drop 1ph/3ph with R & X at operating temperature, %% of nominal, and the smallest size for the limit
-
ELE-013 Motor Full-Load Current & Starting
FLC, input kW, start current & speed (50 Hz)
-
ELE-014 Motor Overload & Protection
Overload setting/class, AC-3 contactor & SCPD for a 3-phase motor (AS/NZS 3000 / IEC 60947-4-1)
-
ELE-015 Power Factor Correction
Capacitor kVAR & uF to reach a target power factor
-
ELE-016 Single Phase Capacitors
Start & run capacitor selection for 240 V pump motors
-
ELE-017 Earth Electrode Resistance
Driven earth rod(s) resistance from soil resistivity (Dwight; AS/NZS 3000 / AS 1768)
-
ELE-018 Fault Loop Impedance
Max Zs for an MCB to trip instantly (AS/NZS 3000 Cl 5.7.4)
-
ELE-019 Generator Sizing
Size a diesel generator off max site amps + pick an Able Power model
-
ELE-020 Lighting / Luminaire Count (Lumen Method)
Number of luminaires for a target lux over a floor area (shed, pump room, plant)
-
ELE-021 Maximum Demand
AS/NZS 3000 App C max demand - domestic & commercial, 1ph/3ph
-
ELE-022 UPS / DC Backup Battery Sizing
Battery capacity (Ah) to back a load for a set time, with depth-of-discharge & ageing derating
-
ELE-023 Electrical Formulas (Ohm's Law & Power)
V, I, R, P, kVA, kVAR & kW<->HP for DC / 1ph / 3ph