WTR-022
Water analysis interpretation software
Preserve mixed units and non-detects, find missing evidence and review a worked bore-water example.
Read the interpretation guideFiltration, disinfection, dosing and membrane / RO design sized to your feed water and your target. Built for treatment and process engineers.
Water treatment software guides
Start with water analysis and treatment selection, or open the guide for a specific process. Each guide explains the required inputs, shows a worked example and identifies checks needed before equipment selection.
WTR-022
Preserve mixed units and non-detects, find missing evidence and review a worked bore-water example.
Read the interpretation guideTreatment workflow
Connect water-quality findings to preliminary process stages and the correct sizing calculator.
Review the process mapDOM-004 · WTR-018
Check resin, service flow, vessel size, salt use and regeneration for domestic and industrial duties.
See both worked examplesWTR-015
Assess a DMI-65 vessel, media, oxidant, dosing pump and backwash duty from bore-water results.
Read the iron-removal guideWTR-003
Build a preliminary brackish-water RO array and feed, permeate and concentrate balance.
Review the RO exampleWTR-006
Size preliminary UF modules, racks, recovery, backwash and air-scour requirements.
Review the UF exampleA short introduction to what Tenselo covers in this category.
Video summary: Preliminary interpretation of laboratory results, treatment selection, softening, iron removal, reverse osmosis, ultrafiltration, dosing and disinfection.
8″ spiral-wound brackish · Codeline 80S vessels
These figures come from the Tenselo engine. Every result Tenselo produces shows the inputs it used and the method behind it, so the work can be checked rather than taken on trust.
Element count, vessels and flux matched to the feed water and recovery — named to real product.
Rejection, CT disinfection and LSI scaling all checked against the target.
Coagulant, antiscalant and disinfectant rates sized to flow and chemistry.
From laboratory results to a treatment assessment
Tenselo's water test interpretation software helps water professionals assess laboratory results and develop a preliminary treatment approach. WTR-022, Drinking Water Analysis, combines the entered results with the water source, flow and pressure, then links proposed treatment stages to detailed sizing calculators.
Read the full water-analysis interpretation guide and worked bore-water example.
Enter each tested parameter from the laboratory report, including its unit and any less-than reporting limit. Mixed units can be entered per result. Leave untested parameters blank: a missing result is not a measured zero, and a non-detect does not prove a concentration is below a guideline when the reporting limit is too high.
The assessment screens entered drinking-water results against guideline values and flags missing evidence, hardness inconsistencies and scaling concerns. Source conditions affect the assessment: bore water, rainwater, surface water, regulated mains and recycled water require different questions. Proposed process stages may include sediment filtration, iron removal, softening, membranes, carbon or disinfection, depending on the inputs.
Use the linked calculators to investigate stage capacity, dosing and operating requirements. Check available pressure, variable water quality, backwash arrangements and supplier performance data before selecting equipment. The output is a design aid for specialist review; it is not drinking-water certification or a final equipment specification.
For crop and emitter considerations, use the irrigation water-quality tools, including sodium hazard, leaching requirement and emitter-clogging risk. For filter capacity and selection, explore filtration calculators. These checks answer different questions from a drinking-water assessment.
New accounts require approval. Public descriptions explain the workflow; running the calculators requires authorised application access.
This hypothetical example was run in Tenselo's WTR-022 Drinking Water Analysis calculator on 15 September 2026. It shows how the software records mixed laboratory units and missing tests before a water professional reviews treatment options. It is a static demonstration, not a customer laboratory report or a drinking-water clearance.
The example uses a bore-water supply with a design flow of 60 L/min (3.60 m³/h), 350 kPa available pressure and eight operating hours per day. Additional entered values are pH 7.2, TDS 450 mg/L, turbidity 1.2 NTU, temperature 18 °C and alkalinity 180 mg/L as CaCO3.
| Parameter | Entered value | Displayed result |
|---|---|---|
| Electrical conductivity | 0.75 mS/cm | 750 µS/cm; original units retained |
| Iron | 800 µg/L | 0.80 mg/L; flagged for further assessment |
| Arsenic reporting limit | <2 µg/L | <0.0020 mg/L; the less-than qualifier is retained |
| Total hardness | 250 mg/L as CaCO3 | Flagged for further assessment; the hardness basis is retained |
| Manganese | Left blank | Not tested; no zero concentration assumed |
| Microbiology | E. coli and total coliforms not tested | Cannot confirm fitness for drinking; microbiological testing required |
The calculation preserves the difference between an entered concentration, a less-than reporting limit and an untested parameter. It identifies hardness and iron for further assessment and explicitly reports that drinking-water suitability cannot be confirmed from these inputs.
This is a focused summary of the input interpretation, not the complete treatment design. A proposed treatment process still needs review of the complete laboratory analysis, flow, available pressure, source variability and supplier performance data. Live calculations require authorised Tenselo application access.
Review the complete bore-water filtration and treatment pathway, then continue to water softener sizing, iron-removal assessment or domestic filtration to see the separate sizing questions. Check access and availability.
After interpreting a water test, choose a sizing tool for the treatment stage being assessed. Tenselo includes separate calculators for hardness removal, iron and manganese filtration, reverse osmosis and ultrafiltration. Each stage needs its own flow, water-quality and operating assumptions.
WTR-018, Water Softener (Industrial), uses service flow, total hardness and daily water use to assess resin volume, vessel configuration, salt usage and regeneration frequency. Enter hardness with its stated basis, such as mg/L as CaCO3, and distinguish peak flow from average daily demand.
For a house or light-commercial supply, use DOM-004, Domestic Water Softeners. Check the required flow through the bed as well as the hardness load between regenerations. Iron in the water needs assessment before treating the softener as the complete solution.
WTR-015, Iron Removal Filter (DMI-65), assesses an iron-removal stage using flow and iron, manganese and hydrogen sulphide inputs. Its outputs cover chlorine dosing, filter vessels and backwash requirements. Confirm the water analysis, pressure and operating conditions before choosing a treatment arrangement.
A media name alone does not establish suitability. Review the DMI-65 technical data with the supplier, including oxidation and backwash requirements. If membrane treatment follows, assess compatibility between the upstream chemicals and the selected membrane.
The WTR-003 reverse osmosis calculator supports preliminary brackish-water RO sizing from the required product-water flow, operating hours, feed-water analysis and selected membrane and vessel. Review recovery, feed and concentrate flows, membrane arrangement, pump duty and the estimated permeate quality together.
Related tools cover RO permeate blending and RO performance and mass balance. A final design needs manufacturer performance checks, pretreatment review and a plan for concentrate disposal. DuPont's RO technology overview explains why salt rejection depends on the membrane, feed conditions and system design.
WTR-006, UF Design, supports ultrafiltration skid sizing from product flow, feed-water type, water-analysis inputs and the selected module. Assess module and rack requirements, flux, backwash, air scour, cleaning requirements and recovery. State whether the required flow is net product flow after cleaning and backwash allowances.
Ultrafiltration and reverse osmosis answer different treatment questions. Do not select either process from its name alone: compare the feed-water analysis, required treated-water quality and manufacturer performance data. Treatment sizing is a design aid and does not certify drinking-water safety.
These are public descriptions of account-based calculators. New accounts require approval; see access and availability. Use the water-test interpretation workflow to identify missing information, then have the proposed treatment and equipment reviewed by a competent specialist.
Every calculator in this category, by its reference code. Running them requires an approved Tenselo account with access to the relevant calculators.
Re-mineralising/pH correction contactor: bed volume, calcite use and CO2 demand
Cl2:ammonia ratio, chlorination regime and dose for monochloramine or breakpoint
Brackish RO skid - elements, vessels & length, array, skid size, HP pump, recovery, permeate TDS, scaling & energy
Bypass fraction to hit a target TDS or hardness
Recovery -> flows, reject TDS, salt passage, osmotic pressure
Ultrafiltration skid sizing - modules, flux, backwash, air scour, CEB chemicals, recovery & permeate quality
Disinfection CT check from tank volume, flow & baffling (USEPA SWTR Giardia free chlorine)
Free-chlorine residual after a contact/travel time (first-order decay) + re-dose
Ozone generator sizing & selection
UV disinfection reactor sizing & selection
Flow + duty -> EBCT, GAC vessel(s), carbon mass & backwash
Number of cartridges and housing size for a duty flow and micron rating
Coagulant dose -> chemical feed (kg/day & solution L/day) + rapid-mix / floc G-value and G.t
Protein skimmer / foam fractionator sizing & selection
Fe/Mn/H2S + flow -> chlorine dose & pump, DMI-65 vessel(s), backwash
Packed-tower air:water ratio, packing depth & diameter for stripping dissolved gas (screening / indicative)
Two-bed cation+anion resin, regenerant & run length
Hardness + flow -> resin, vessel(s), salt usage & regen frequency
Surface blowdown, make-up & heat loss from steam load + TDS
Evaporation, blowdown, make-up & cycles of concentration
HRT, turnovers & disinfection contact time (T10, CT)
Source + water sample -> guideline screening and preliminary treatment stages
Heat duty + area sizing & selection (LMTD)
Tell us about yourself and the work you do. We review each application before granting access. The 14-day trial requires no payment card.
After approval, verify your email and set your password. Your account shows the time left in your trial. When it ends, choose a paid plan and review the price in Stripe before subscribing.
Start 14-day free trialAlready approved? Sign in. For company licences, email sales@tenselo.com.au.