Flowmeter and instrumentation calculators
4–20 mA scaling, sensor ranging and loop budgets without the head-scratching. Built for the instrument techs and electricians who commission water plants.
4–20 mA current loop
Linear scaling + loop resistance budget
The figures shown are an indicative worked example. Every result Tenselo produces shows the inputs it used and the method behind it, so the work can be checked rather than taken on trust.
Why it matters on the job
Scaling that's right
Engineering units mapped to 4–20 mA so SCADA reads exactly what the sensor sees.
Loops that drive
Resistance budget vs supply checked so the transmitter has the headroom to work.
Signals that survive
Cable run, volt-drop and noise margins sorted before you energise.
Flowmeter pulse output and instrumentation calculations
Tenselo includes instrumentation calculators for water-meter pulse scaling, flowmeter installation, analogue signals, current loops and control-system sizing. Use the meter's configured output and the receiving instrument's input requirements when checking how a flow measurement will be displayed or recorded.
Flowmeter K-factor and pulse scaling calculator
INS-004, Flowmeter K-Factor / Pulse Scaling, converts pulse frequency to flow, flow to pulse frequency, or total pulses to volume. Its K-factor inputs use pulses per litre or pulses per cubic metre. Check whether the meter documentation instead states litres per pulse; that is the reciprocal convention and must be converted before entering a pulses-per-volume value.
Static worked example: a K-factor of 2 pulses per litre and a frequency of 20 Hz give 20 / 2 = 10 L/s, or 600 L/min and 36 m³/h. A total of 10,000 pulses at that K-factor represents 5,000 litres, or 5 m³. This example illustrates the scaling arithmetic; commissioning also requires the correct meter configuration and counter settings.
Flowmeter straight-length calculator
INS-005, Flowmeter Straight-Length, compares available upstream and downstream pipe runs with guidance based on meter type, pipe bore, upstream fittings and the selected flow-conditioner assumption. Treat the result as an installation check against stated assumptions. The exact manufacturer's instructions remain necessary; there is no single straight-length rule for every meter.
For preliminary meter size and output selection, use HYD-029, Water Meter Sizing. Size selection and signal scaling answer separate questions: a correctly scaled counter does not establish that the meter is suitable for the flow duty.
Analogue scaling and 4–20 mA loops
The catalogue also includes analogue signal scaling, 4–20 mA loop resistance budgeting, differential-pressure flowmeter square-root scaling and pressure-transducer range selection. Match each calculation to the signal type and instrument configuration.
New accounts require approval. These public descriptions and the static example explain the tools; running project calculations requires authorised application access. See availability and registration. Review instrument selection and commissioning with a competent person.
14 Instrumentation & Control calculators
Every calculator in this category, by its reference code. Running them requires an approved Tenselo account with access to the relevant calculators.
-
INS-001 4-20 mA Loop Resistance Budget
2-wire (loop-powered) transmitter: will the supply drive 4-20 mA through the sense resistor, barrier & cable?
-
INS-002 Analog Signal Scaling
Convert 4-20 mA / 0-10 V / 1-5 V / raw counts to/from engineering units, with PLC raw scaling (8/12/16-bit) & under-range
-
INS-003 DP Flowmeter Square-Root Scaling
Differential-pressure flow (orifice/venturi) where flow is proportional to sqrt(DP) - signal <-> flow with low-flow cutoff
-
INS-004 Flowmeter K-Factor / Pulse Scaling
Pulse-output flowmeter (turbine/paddlewheel/mag): K-factor -> flow rate & totalised volume, both ways
-
INS-005 Flowmeter Straight-Length
Upstream/downstream straight pipe a flowmeter needs for accuracy
-
INS-006 Level Sensor Range & Scaling
Measuring span, 4-20 mA scaling, resolution and top/bottom blanking
-
INS-007 Pressure Transducer Range Selection
Pick a sensor range from normal/surge pressure with good turndown and accuracy
-
INS-008 Control Transformer VA Sizing
Size a control/isolation transformer for the continuous (sealed) load and the inrush of the largest device
-
INS-009 Instrument Air Demand & Receiver
Air demand, receiver volume and compressor FAD for pneumatic actuators
-
INS-010 PLC I/O & Control Panel Power
I/O card count (with spares) and the 24 V DC panel supply
-
INS-011 RTU Solar / Battery Autonomy
Battery Ah and solar watts for an off-grid telemetry outstation
-
INS-012 VSD / Soft-Starter Selection
Drive & soft-starter sizing, start method vs DOL inrush (IEC 60947-4 / 61800)
-
INS-013 SCADA Poll / Scan Capacity
Scan-cycle time, channel utilisation and how many RTUs fit the poll rate
-
INS-014 Telemetry Data Budget
Monthly cellular data per remote site from poll rate and payload
Start your 14-day free trial